Survey of heating, underfloor heating and heat nodes
We check heating circuits, manifolds, pump groups, automation, radiators, underfloor heating, balancing and the actual thermal mode of rooms.
The survey aims to find the cause of cold zones, overheating, noise, uneven heating, leaks and unnecessary operating costs.

Finding cold zones, overheating, uneven heating and control errors.
Checking assembly, balancing, access, labels and suitability for the property.
Diagnostics of circuits, actuators, air in the system and quality of control.
What the survey includes
We check not only visible components, but also the hidden system logic: routes, loads, access, safety, finish-related risks and future operation.
- heat-carrier distribution by zones
- balancing of circuits and branches
- temperature schedules and actual modes
- signs of air and hydraulic imbalance
- manifolds, pumps and mixing units
- thermostats, servos and sensors
- room-by-room control logic
- maintenance access
- leaks and moisture marks
- underfloor heating mistakes
- overheating zones under finishes
- poor penetrations and insulation
- what can be adjusted without dismantling
- which nodes should be replaced as planned
- how to add zone control
- how to prepare the system for commissioning
Instrument checks and records
The survey format is selected for the property. Where needed, we use video inspection, thermal imaging, measurements, photo records and analysis of existing schemes.
Shows the real heating pattern, underfloor heating operation, cold zones and anomalies.
We record temperatures, circuit behavior, pump and automation operation.
We check manifolds, valves, labels, access and assembly quality.
We define the technical cause and the correction plan by stages.
Where a survey is especially important
This diagnosis is needed where an engineering error is expensive: finishes, operation, deadlines and the project reputation.
Checking hidden engineering risks before finishing, purchase, renovation or rework.
Diagnostics of technical rooms, long routes, redundancy and interaction between systems.
Checking loads, water, sewerage, ventilation, electrical systems and downtime risks.
Special attention to humidity, condensation, safety, drainage and service access.
Checking comfort, noise, control nodes, hidden defects and readiness for operation.
Assessment of safety, marking, access, redundancy and clear operation.
How the survey is carried out
We follow a clear sequence: record the initial data, check the system, separate urgent risks from planned work and give the owner a clear picture.
We clarify the property type, symptoms, renovation stage, access to nodes, documents and finish-related limits.
We check accessible areas, technical rooms, shafts, cabinets, routes, equipment and actual assembly.
When required, we use a camera, thermal imager, measurements, test starts and operating-mode checks.
We separate visible symptoms from the cause: routing, equipment selection, installation, automation or operation.
We divide urgent risks, planned corrections and tasks that can be done during the next renovation stage.
We provide conclusions, photos, a defect list, recommendations and a clear structure for further work.
What the client receives
The survey result is not a set of general phrases, but a clear list of risks, priorities and technical actions.
Actual condition, identified defects, risks, causes and priorities for correction.
What to fix immediately, what to schedule, what to check further and which nodes to monitor.
Survey materials that can be shared with the owner, manager, designer or contractor.
Solutions for upgrade, repair, installation, access, automation and future maintenance.
Survey of heating, underfloor heating and heat nodes
Tell us the property type, system and issue. We will suggest the survey format and the checks required.